Created on 08-11-2008 05:59 AM Edited on 12-16-2021 11:02 AM
Article
Alert Message Console logs were enhanced in FortiManager 3.0 MR7 to help users better understand log messages concerning installed configurations and RAID disk status.
Enhanced terminology is now used for these log messages concerning a failed installation configuration. For example, "June 21, 19:18:54 -- Save Revision Configuration for device (FGT_50A) failed! Reason: Configured Firewall Address count is greater than the capacity (1000) of device in virtual domain 'root'".
The following RAID log messages were changed in FortiManager 3.0 MR7 to help users clearly identify and understand the status of a RAID disk. The log messages are found in the Alert Console of the System Settings module.
RAID log messages can also be found in the event log and are logged at the notification log severity level.
Previous RAID log messages | MR7 RAID log messages |
3w-9xxx: scsi0: AEN: WARNING (0x0 : 0x0019) : Drive removed:port=0 | RAID disk1 removed |
3w-9xxx: scsi0: AEN: ERROR (0x04: 0x002) : Degraded unit:unit=0, port=0 | RAID degraded |
3w-9xxx: scsi0: AEN: WARNING (0x0 : 0x0019) : Drive removed:port=2 | RAID disk3 removed |
3w-9xxx: scsi0: AEN: ERROR (0x04: 0x002) : Degraded unit:unit=0, port=2 | RAID degraded |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x001A) : Drive inserted:port=0 | RAID disk1 inserted |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x001A) : Drive inserted:port=2 | RAID disk3 inserted |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x000B) : Rebuild started:unit=0, subunit=0 | RAID rebuild started |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x000B) : Rebuild started:unit=0, subunit=1 | RAID rebuild started |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x0005) : Rebuild completed:unit=0, subunit=0 | RAID rebuild completed |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x0005) : Rebuild completed:unit=0, subunit=1 | RAID rebuild completed |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x0007) : Initializing completed:unit=0 subunit=0 | Initialize completed |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x000C) : Initializing started:unit=0 subunit=0 | Initialize started |
3w-9xxx: scsi0: AEN: INFO (0x04: 0x003C) : Initializing paused:unit=0 subunit=0 | Initialize paused |