This article will describe a step that may be missed by users when they are trying to configure EMC Clariion.

 

With the information provided below, Look at values for Prct Busy and Prct Idle.  If the values here are "not available", then you have not completed step 6 of the configuration for EMC Clariion.

 

Getting to the last Step of EMC Clariion's configuration there's a test against the Remote Storage Device:

[admin@B2945-Collector tmp]$ /opt/Navisphere/bin/naviseccli -h xxx.xxx.xxx.xxx -User xxxxxxxxx -Password xxxxxxx -Scope global getall -sp
SP Information
--------------
    
    
Storage Processor:                   SP A
Storage Processor Network Name:      xxxxxxxxxxxx
Storage Processor IP Address:        xxx.xxx.xxx.xxx
Storage Processor Subnet Mask:       255.255.255.0
Storage Processor Gateway Address:   xxx.xxx.xxx.xxx
System Fault LED:               OFF
Statistics Logging:             OFF
SP Read Cache State             Enabled
SP Write Cache State            Enabled
Max Requests:                   N/A
Average Requests:               N/A
Hard errors:                    N/A
Total Reads:                    0
Total Writes:                   0
Prct Busy:                      Not Available
Prct Idle:                      Not Available
System Date:                    09/18/2013
Day of the week:                Wednesday
System Time:                    13:19:37
Read_requests:                  0
Write_requests:                 0
Blocks_read:                    0
Blocks_written:                 0
Sum_queue_lengths_by_arrivals:  0
Arrivals_to_non_zero_queue:     0
Hw_flush_on:                    0
Idle_flush_on:                  0
Lw_flush_off:                   0
Write_cache_flushes:            0
Write_cache_blocks_flushed:     0
Internal bus 1 busy ticks:      N/A
Internal bus 1 idle ticks:      N/A
Internal bus 2 busy ticks:      N/A
Internal bus 2 idle ticks:      N/A
Internal bus 3 busy ticks:      N/A
Internal bus 3 idle ticks:      N/A
Internal bus 4 busy ticks:      N/A
Internal bus 4 idle ticks:      N/A
Internal bus 5 busy ticks:      N/A
Internal bus 5 idle ticks:      N/A
Controller busy ticks:          0
Controller idle ticks:          0

 

Here is Step 6 from the Configuration/User's Guide:

Make sure that the Analyzer module is on - otherwise the performance metrics will not be available and discovery will fail.

 

Here is what those two Values should look like:

Prct Idle:        0
Prct Busy:        0
    

 

Please go through Step 6 on your EMC Clariion and turn on the Analyzer Module.

Additional Information

When running the naviseccli command, put the IP of the Storage Processor and not the Control Station.

 