NOTE: FortiNAC is now named FortiNAC-F. For post-9.4 articles, see FortiNAC-F. FortiNAC is a zero-trust network access solution that provides users with enhanced visibility into the Internet of Things (IoT) devices on their enterprise networks.
FortiKoala
Staff
Staff
Article Id 192563

Description

 

This article describes the behavior where a single false positive 'Database Replication Error' alarm is generated on occasion. The process used for database replication is robust and will restart database replication automatically. Therefore, a single alarm can be ignored.  

Scope

Version: 8.x, 9.x., F7.x.

Solution
 
The default values of the 'Database Replication Error' alarm mapping were changed in newer releases. The 'one Event to one Alarm' mapping was changed to a 'Frequency' mapping of 'three Event occurrences in two minutes per Alarm'.  

The database change does not occur automatically for existing customers during a software upgrade.  Existing customers are required to manually change the Event to Alarm mapping.

To modify the Event to Alarm mapping, follow the instructions in the appropriate Administration Guide:

 

Modify the Database Replication Error mapping.

  • Trigger Rule = Event Frequency.
  • Frequency values = 3 events occurring within 2 minutes.


If the Database Replication Error alarm still triggers with this frequency mapping, then further investigation is needed. See the related KB article Technical Tip: Database replication Error in a FortiNAC HA setup.