FortiNAC
NOTE: FortiNAC is now named FortiNAC-F. For post-9.4 articles, see FortiNAC-F. FortiNAC is a zero-trust network access solution that provides users with enhanced visibility into the Internet of Things (IoT) devices on their enterprise networks.
FortiKoala
Staff
Staff
Article Id 189755
Description
SNMPv3 communication to devices becomes unsuccessful over time.  Initial SNMPv3 communication is successful, but subsequent reads are not.  This is an acknowledged problem with NAC’s SNMPv3 stack.

Symptoms include:
- L3 and/or L2 Polling failures using SNMPv3.
- Credential validation test fails for SNMP in Topology view.  However, the SNMPv3 credentials have been confirmed to be correct and worked previously.  A snmpwalk of the affected device from NAC CLI also works.
- Clicking the "Clear Engine ID" button does not clear the condition.

 

Scope
Version: 8.1.0 and lower

Solution
Workaround: Restart NAC's processes to clear the failure condition and resynchronize the SNMPv3 stack for successful SNMP communication.

Solution:  Addressed in Network Sentry version 8.1.1 and higher.