FortiNAC
NOTE: FortiNAC is now named FortiNAC-F. For post-9.4 articles, see FortiNAC-F. FortiNAC is a zero-trust network access solution that provides users with enhanced visibility into the Internet of Things (IoT) devices on their enterprise networks.
FortiKoala
Staff
Staff
Article Id 194773
Description
Appliance no longer registering or deleting devices that have been enrolled or deleted in Airwatch.  Test Communication succeeds but polling fails.  Administration UI displays a 429 error when attempting to "Poll Now".

Example from Network Sentry output.master log:
AirWatchServer: HTTPException(status code = 429)

A 429 error code indicates the Airwatch device has received too many requests from the appliance in a given amount of time.  This results in the Airwatch device no longer responding to any additional requests.

Scope
Version: 8.x and above.

Solution
There are 2 settings in Airwatch that can be modified.  Contact Airwatch support for assistance.
  • The maximum allowed number of calls that can be polled per minute can be overridden. Remove the overridden maximum value.
  • Increase the number of polls that can be made.

Configure the appliance to perform less queries.
Navigate to System > Settings > MDM Services (8.x) or Network > Service Connectors (9.x) and modify the below settings:
  • Disable Application Updating.
  • Change Automatic Registration Polling to 1 per Day.
  • Disable Revalidate Health Status on Connect.




Related Articles

Technical Tip: Troubleshooting MDM registration issues