Created on 10-04-2019 04:44 AM Edited on 02-13-2024 04:39 AM By Stephen_G
Description
This article explains the method to identify what type of RAID the FortiAnalyzer/FortiManager device is running.
If a hard disk on a FortiAnalyzer/FortiManager unit fails, it must be replaced.
On FortiAnalyzer/FortiManager devices that support hardware RAID, the hard disk can be replaced while the unit is still running - known as hot swapping.
On FortiAnalyzer/Fortimanager units with software RAID, the device must be shutdown prior to exchanging the hard disk.
Scope
FortiAnalyzer and FortiManager.
Solution
Use command line to check if the device uses hardware or software RAID.
To check RAID type from the command line:
diagnose system raid status
The following information is shown in the output:
Mega RAID : this output shows that the device uses hardware RAID.
Software RAID : this output shows that the device uses software RAID.
Sample command line output showing RAID:
diagnose system raid status
Mega RAID: <- This is hardware RAID.
RAID Level: Raid-50
RAID Status: OK
RAID Size: 11175GB
Groups: 2
diagnose system raid status
Software RAID: <- This is software RAID.
RAID Level: Raid-50
RAID Status: OK
RAID Size: 11175GB
Groups: 2