FortiNAC
NOTE: FortiNAC is now named FortiNAC-F. For post-9.4 articles, see FortiNAC-F. FortiNAC is a zero-trust network access solution that provides users with enhanced visibility into the Internet of Things (IoT) devices on their enterprise networks.
cmaheu
Staff
Staff
Article Id 189670

Description


CLI credential validation fails for Arista switches configured to require typing "enable" to enter enable mode, but no password is needed.
Scope


Version: 8.x

Solution

Workaround:
1.  Configure switch to require enable password.
2.  Click on the Credentials tab for the affected Arista switch model.
3.  Under CLI Settings, populate the Enable Password field with the new password.
4.  Click Validate Credentials to verify CLI access now completes.
5.  Click Save.
 
Solution
 
 To be addressed in version 8.7.2.
1.  Upgrade appliance to version 8.7.2 or higher.
2.  Once upgraded, click on the Credentials tab for the affected Arista switch model.
3.  Under CLI Settings, populate the Enable Password field with the # character.
4.  Click Validate Credentials to verify CLI access now completes.
5.  Click Save.
 
If behavior persists, refer to the related KB article below for additional troubleshooting steps.

 

Related Articles

Troubleshooting CLI credential failure

SSH login fails due to SSH keyboard-interactive settings