FortiGate
FortiGate Next Generation Firewall utilizes purpose-built security processors and threat intelligence security services from FortiGuard labs to deliver top-rated protection and high performance, including encrypted traffic.
jintrah_FTNT
Staff
Staff
Article Id 197624

Description


Sometimes the FPC is found disconnected from the fabric and is required to reimage the same, or when firmwares of FPC and MBD are different, the FPC is reimaged with the same firmware running on MBD.


Scope


For FortiGate-6000F.

Solution


1) Check the status of FPC module and ensure that the Base connectivity for the FPC is noted Up.

 

#diagnose load-balance status
==========================================================================
MBD SN: F6KF31Txxxxxxxxx
  Master FPC Blade: slot-1

     Slot  1: FPC6KFTxxxxxxxx
       Status:Working   Function:Active
       Link:      Base: Up          Fabric: Up
       Heartbeat: Management: Good   Data: Good
       Status Message:"Running"
     Slot  2:
       Status:Dead      Function:Active
       Link:      Base: Up          Fabric: Down   <-----
       Heartbeat: Management: Failed Data: Failed
       Status Message:"Waiting for management heartbeat."
       ...

Note.
If Base and Fabric is found down, it indicates that the slot is powered down or shutdown.
In that case, try to power on the slot and check if the FPC joins the fabric and move Status to Working state.

( # execute load-balance slot power-on <slot_id>)

2) To update the firmware on FPC from the MBD use the command below:

 

#execute load-balance update image <slot_id>