FortiAuthenticator
FortiAuthenticator provides access management and single sign on.
matanaskovic
Staff
Staff
Article Id 192453
Description
This article shows how to change the default code refresh timer from 60 seconds to 30 seconds for FortiToken Mobile only.   

Scope
FortiAuthenticator 4.0

Solution
The following steps can be used to change the timer value:

1) Login to FortiAuthenticator admin GUI page.

2) Go to
System -> Administration -> FortiGuard.

3) Expand the 'FortiToken Mobile Provisioning' tab.

4) Select 30 on 'Time step:' and select 'OK' to save the setting as shown below.


This will only be applied to new provisioning FortiToken.  
If it is required to change for an existing FortiToken then it must be removed from the user account and provisioned again.